Switch Mode Power Supply (SMPS) Uninterruptible Power Supply (UPS) Power Factor Correction (PFC) LLC Half-bridge Charger
Absolute Maximum Ratings TC = 25ºC, unless otherwise noted
Symbol
|
Parameter
|
|
Unit
|
VDSS
|
Drain-Source Voltage
|
600
|
V
|
ID
|
Drain Current - Continuous (TC = 25℃)
- Continuous (TC = 100℃)
|
47
29
|
A
|
IDM
|
Drain Current - Pulsed (Note 1)
|
140
|
A
|
VGSS
|
Gate-Source voltage
|
±30
|
V
|
EAS
|
Single Pulsed Avalanche Energy (Note 2)
|
1160
|
mJ
|
IAR
|
Repetitive Avalanche Current (Note 1)
|
10
|
A
|
EAR
|
Repetitive Avalanche Energy (Note 1)
|
1.72
|
mJ
|
dv/dt
|
Peak Diode Recovery dv/dt (Note 3)
|
15
|
V/ns
|
dVds/dt
|
Drain Source voltage slope (Vds=480V)
|
50
|
V/ns
|
PD
|
Power Dissipation (TC = 25℃)
|
391
|
W
|
TJ, TSTG
|
Operating and Storage Temperature Range
|
-55 to +150
|
℃
|
TL
|
Maximum Lead Temperature forSoldering Purpose,
1/8” from Case for 5 Seconds
|
300
|
℃
|